Welwyn Tunnel rail crash
51°50′10″N 0°11′10″W / 51.836°N 0.186°W / 51.836; -0.186
The Welwyn Tunnel rail crash took place in Welwyn North Tunnel, north of Welwyn (now Welwyn North) station on the Great Northern Railway, on 9 June 1866.[1] According to L T C Rolt, "from the point of view of damage to engines and rolling stock it was one of the most destructive in railway history."[2]
Background
There are two tunnels between Welwyn station and Knebworth on the East Coast Main Line, known as Welwyn South Tunnel and Welwyn North Tunnel. In 1866, traffic through the tunnels was operated using a form of block working - the signalmen at Welwyn and Knebworth communicated with each other via a telegraph system, and were not permitted to signal a train into the tunnels until they had received confirmation that the previous train had cleared the section. The instrument was a "speaking" telegraph, which was used for general communication between the signal boxes.
Trains involved
The first train involved in the accident consisted of 38 empty coal wagons, hauled by a tender locomotive.[1] The second train was a Midland Railway goods train from London, with 26 wagons. The third train was a Great Northern express freight train, carrying meat from Scotland for Smithfield Market.[2]
Sequence of events
The train of coal empties was signalled away from Welwyn at 23:20. When passing through the North tunnel, the engine failed and the train came to a stand. At first, guard Wray recommended that the train be allowed to roll back on the falling gradient to Welwyn, but the driver refused, as such a move would be dangerous and contrary to the rules. According to regulations, Wray should have placed detonators on the line to protect the rear of his train, but he did not, and he also failed to communicate with either signal box.
At 23:36, the Midland Railway goods train stopped at Welwyn signal box. The signalman at Welwyn, who had not received the "out of section" signal for the train of coal empties, sent a telegraph message to Knebworth asking if it had cleared the tunnel. The Knebworth signalman stated to the official enquiry that he had replied with the code for "No", but the Welwyn signalman claimed that he had received a "Yes". The code for "No" differed from the code for "Out" only by the number of beats on the telegraph needle,[1] and the enquiry ruled that the Welwyn signalman had misinterpreted the signal as being "Out", which would have the same meaning as "Yes" in answer to his question. He therefore cleared his signals and allowed the Midland train into the tunnel.
The Midland train ran into the stationary first train at a speed estimated between 20 and 25 miles per hour (32 and 40 km/h). The driver had no warning of its presence, and the collision killed Wray whilst severely injuring Rawlins, an employee of the Metropolitan Railway, who was travelling in the guard's van contrary to the regulations of the Great Northern Railway. Rawlins succumbed to his injuries and died on the morning of 12 June. The driver and fireman of the Midland train were not seriously injured, but it took them some time to extricate themselves from the debris of the accident.
Before any of the railwaymen could communicate with either signal box, the up meat train was allowed into the tunnel, where it struck the wreckage from the first collision and caught fire. Due to the difficulty of accessing the tunnel after the accident, and because it was directly beneath one of the tunnel's ventilation shafts, the fire was not extinguished until 11 June. According to Rolt, "all that night and all through the next day the ventilation shaft belched flames, smoke and the smell of roasting meat over the surrounding countryside."[2]
Investigation and consequences
The official report, by Captain F. H. Rich of the Royal Engineers, blamed the collision mainly on Guard Wray of the first train, for failing to protect the rear of his train after it had stopped, and for relying on the signals for protection in this situation.[1] A secondary cause was the misreading of the telegraph message by the Welwyn signalman. Rich recommended two changes to the signalling method, which were subsequently adopted in the system of absolute block working - before a train is allowed into a section, the signalman must positively request clearance from the next box ahead, rather than relying on the "out of section" message for the previous train, and a separate block telegraph that permanently displays the state of the section should be used, in addition to the general-purpose "speaking" telegraph.
Similar accidents
- Clayton Tunnel rail crash (1861)
- Norton Fitzwarren rail crash (1890)
- Winwick rail crash (1934)
See also
References
- ^ a b c d Rich, Capt F H (1866). Accident Returns (PDF). Board of Trade.
- ^ a b c Rolt, L.T.C. (1976). Red for Danger. Pan. ISBN 0-330-25555-X.
- v
- t
- e
- Philadelphia (Jul 1815)
- Parkside (Sep 1830)
- Wetheral (Dec 1836)
- Harrow (Aug 1838)
- Howden (Aug 1840)
- Sonning Cutting (Dec 1841)
- Penistone (Oct 1845)
- Dee Bridge (May 1847)
- Sutton Tunnel (Apr 1851)
- Burnley (Jun 1852)
- Straffan (Oct 1853)
- Reading Southern (Sep 1855)
- Lewisham (Jun 1857)
- Round Oak (Aug 1858)
- Helmshore (Sep 1860)
- Atherstone (Nov 1860)
- Wootton (Jun 1861)
- Clayton Tunnel (Aug 1861) ‡
- Kentish Town (Sep 1861)
- Winchburgh (Oct 1862)
- Rednal (Jun 1865)
- Staplehurst (Jun 1865)
- Welwyn Tunnel (Jun 1866)
- Yanwath (Feb 1867)
- Warrington (Jun 1867)
- Abergele (Aug 1868) ‡
- Maesycwmmer (Jun 1869)
- Dalton Junction (Dec 1869)
- Newark (Jun 1870)
- Tamworth (Sep 1870)
- Stairfoot (Dec 1870)
- Hatfield (Dec 1870)
- Kirtlebridge (Oct 1872)
- Wigan (Aug 1873)
- Menheniot (Dec 1873)
- Bo'ness Junction (Jan 1874)
- Thorpe (Sep 1874) ‡
- Shipton-on-Cherwell (Dec 1874) ‡
- Kildwick & Crosshills (Aug 1875)
- Abbots Ripton (Jan 1876)
- Radstock (Aug 1876)
- Heeley (Nov 1876)
- Morpeth (Mar 1877)
- Tay Bridge (Dec 1879) ‡
- Burscough Junction (Jan 1880)
- Wennington Junction (Aug 1880)
- Inverythan (Nov 1882)
- Penistone (Jul 1884) ‡
- Penistone (Jan 1885)
- Hexthorpe (Sep 1887) ‡
- Penistone (Mar 1889)
- Armagh (Jun 1889) ‡
- Norton Fitzwarren (Nov 1890)
- Norwood Junction (May 1891)
- Esholt Junction (Jun 1892)
- Thirsk (Nov 1892)
- Llantrisant (Aug 1893)
- Chelford (Dec 1894)
- St Neots (Nov 1895)
- Snowdon (Apr 1896)
- Menheniot (Feb 1897)
- Welshampton (Jun 1897)
- Penistone (Oct 1897)
- Menheniot (Nov 1897)
- Potters Bar (Mar 1898)
- St Johns (Mar 1898)
- Wellingborough (Sep 1898)
- Wrawby Junction (Oct 1898)
- Potters Bar (May 1899)
1900–1999